| 1 | Indoor Main-Breaker Load Center | Standard residential service, renovations, and small additions | 120/240 V AC, single-phase | 100–200 A | 12–42 circuit spaces; tandem breakers may increase circuit count where permitted | Typically 10 kAIC; verify the rating of the complete breaker assembly | NEMA Type 1 for dry indoor locations | Provides a central disconnect, branch-circuit protection, neutral and grounding termination points, and broad breaker compatibility within the listed system | Not intended for wet or exposed outdoor locations; the service rating must match the calculated electrical load |
| 2 | Outdoor Main-Breaker Load Center | Exterior service equipment, detached structures, workshops, and outdoor utility areas | 120/240 V AC, single-phase | 100–200 A | 12–42 circuit spaces | Typically 10 kAIC; higher ratings are available for specific installations | NEMA Type 3R for rain-resistant outdoor use | Weather-resistant enclosure, outdoor-rated hubs or conduit entries, and convenient service disconnect capability | Must be installed with correctly sealed openings; Type 3R does not mean submersible or suitable for every corrosive environment |
| 3 | Main-Lug-Only Distribution Panel | Subpanels supplied from an upstream disconnect or main service panel | 120/240 V AC, single-phase | 60–200 A feeder rating | 12–42 circuit spaces | Typically 10 kAIC, subject to the upstream available fault current | NEMA Type 1 indoors or Type 3R outdoors, depending on enclosure | Efficient for distributing power to garages, additions, workshops, and separate building areas without duplicating the service disconnect | Usually does not provide the building's service disconnect; feeder overcurrent protection and a four-wire feeder are required where applicable |
| 4 | High-Capacity Residential Panel | Large homes, electric heating, heat pumps, workshops, and future circuit expansion | 120/240 V AC, single-phase | 200–400 A service capacity | 30–60 circuit spaces | Typically 10–22 kAIC, depending on the listed equipment combination | Usually NEMA Type 1 indoors; outdoor versions commonly use NEMA Type 3R | Higher circuit capacity, improved expansion room, and support for multiple large branch loads when the service calculation permits | A larger panel does not increase available utility capacity; service conductors, meter equipment, and load calculations must be properly sized |
| 5 | Generator-Ready Transfer Panel | Homes and small facilities requiring backup power for selected or essential circuits | 120/240 V AC, single-phase | 100–200 A utility service | 12–42 circuit spaces, often with selected-load management | Typically 10 kAIC; confirm ratings for utility and generator sources | NEMA Type 1 indoors or NEMA Type 3R outdoors | Helps transfer designated loads between utility and generator power while reducing the risk of unsafe backfeeding | Generator output must be compatible with the panel; installation requires correct transfer equipment, grounding, bonding, and fuel-system planning |
| 6 | GFCI and AFCI-Ready Panel | Modern residential installations where ground-fault and arc-fault protection are required | 120/240 V AC, single-phase | 100–200 A | 12–42 circuit spaces | Typically 10 kAIC | NEMA Type 1 indoors or NEMA Type 3R outdoors | Supports protective devices for shock protection and arc-fault mitigation, with clear circuit identification and convenient branch-circuit expansion | Protection requirements vary by circuit and local electrical code; compatible breakers and correct neutral connections are essential |
| 7 | Compact Space-Saving Panel | Small apartments, accessory structures, remodels, and installations with limited wall space | 120/240 V AC, single-phase | 60–125 A | 6–24 circuit spaces | Typically 10 kAIC | NEMA Type 1 indoors; select models are available in NEMA Type 3R | Smaller footprint, lower material use, and practical circuit distribution for compact electrical systems | Limited expansion capacity; the available circuit count, conductor size, and breaker type must be checked before installation |