| 1 | Compact DIN-rail supply | 100–240 VAC, single-phase | 24 V, 2.5 A | 60 W | About 89% | ≤120 | Often full load to approximately 50°C; reduce load above that point according to the unit’s curve. | Small PLCs, sensors, and control panels |
| 2 | General-purpose DIN-rail supply | 85–264 VAC, single-phase | 24 V, 5 A | 120 W | About 91% | ≤120 | Commonly requires progressive load reduction at elevated ambient temperatures, often above 50°C. | Machine controls and compact automation systems |
| 3 | Mid-range DIN-rail supply | 100–240 VAC, single-phase | 24 V, 10 A | 240 W | About 93% | ≤150 | Check the temperature curve and mounting clearances; enclosure heat can require derating below the published maximum. | Packaging equipment and distributed I/O |
| 4 | High-current DIN-rail supply | 100–240 VAC, single-phase | 24 V, 20 A | 480 W | About 94% | ≤150 | Output capacity may decline at high ambient temperature; verify the manufacturer’s derating curve for cabinet installations. | Robotics, conveyors, and larger control cabinets |
| 5 | Three-phase high-power supply | 3 × 400–500 VAC | 24 V, 40 A | 960 W | About 94% | ≤200 | Thermal limits and airflow are especially important near full load; follow the specified ambient-temperature curve. | Large machinery and centralized 24 V DC distribution |
| 6 | Low-voltage control supply | 85–264 VAC, single-phase | 12 V, 10 A | 120 W | About 90% | ≤120 | Allow for output reduction at elevated ambient temperatures; confirm the permitted operating range for the installation. | Instrumentation, relays, and 12 V control loads |
| 7 | 48 V DIN-rail supply | 100–240 VAC, single-phase | 48 V, 5 A | 240 W | About 92% | ≤200 | Derating is model-specific; check temperature limits and ensure adequate separation from heat-producing equipment. | Telecom peripherals and 48 V industrial devices |
| 8 | High-power 48 V supply | 100–240 VAC, single-phase | 48 V, 10 A | 480 W | About 94% | ≤240 | At high load, use the specified airflow and ambient-temperature derating data; do not assume full output in a sealed cabinet. | Industrial networking and higher-power 48 V loads |
| 9 | High-current 5 V supply | 100–240 VAC, single-phase | 5 V, 20 A | 100 W | About 85% | ≤50 | Confirm output-current limits and cooling requirements; low-voltage, high-current wiring can add significant voltage drop. | Digital electronics, control boards, and test equipment |
| 10 | Redundant-ready 24 V supply | 100–240 VAC, single-phase | 24 V, 20 A | 480 W | About 93% | ≤150 | When used in a redundant arrangement, account for load sharing, module losses, ventilation, and the specified derating curve. | Processes where continuity of control power is important |