| Loop Calibrator | DC current, voltage, loop power, HART-compatible communication on selected models | 0–24 mA measurement and sourcing; commonly 0–10 V; 24 V loop supply on many units | Approximately ±0.02% to ±0.05% of reading for current functions, depending on range and model | Testing transmitters, control valves, I/P converters, signal isolators, and analog input/output loops | Source and simulate modes, loop power, HART access, mA resolution, battery life, and field ruggedness |
| Multifunction Process Calibrator | Voltage, current, frequency, pulse, resistance, RTD, thermocouple, and switch signals | Supports common thermocouple types, Pt100 and other RTDs, resistance, frequency, and process I/O | Electrical functions often about ±0.02% to ±0.05% of reading; sensor accuracy varies by input type | General commissioning, troubleshooting, maintenance, and calibration of transmitters and control systems | Number of supported sensor types, simultaneous measure/source, display readability, documentation, and certification |
| Documenting Process Calibrator | Electrical, temperature, pressure, loop, and calibration-management data | Measures and sources process signals while storing as-found/as-left results and calibration records | Typically similar to the integrated measurement modules; overall uncertainty depends on the selected function | Regulated plants, pharmaceutical production, food processing, utilities, and asset-management programs | Internal memory, audit trail, downloadable reports, user permissions, calibration procedures, and software compatibility |
| Pressure Calibrator | Gauge, absolute, differential, and vacuum pressure; often includes mA and voltage measurement | Typical ranges from low-pressure differential measurement to hundreds of bar, depending on sensor or external module | Common pressure accuracy classes range from approximately ±0.025% to ±0.1% of full scale | Pressure transmitters, switches, gauges, safety systems, hydraulic equipment, and pneumatic control loops | Pressure range, medium compatibility, overpressure protection, process connections, temperature effects, and external modules |
| Temperature Calibrator | RTD, thermocouple, resistance, temperature switches, and temperature transmitters | Sources or measures temperature signals; dry-block and liquid-bath systems may provide controlled physical temperature | Electrical simulation accuracy may be better than ±0.05%; dry-block system accuracy is commonly about ±0.2°C to ±0.5°C | RTD and thermocouple verification, furnace monitoring, environmental systems, laboratories, and process control | Temperature range, stability, uniformity, insert compatibility, reference sensor input, ramp time, and portability |
| Handheld Pressure Pump and Calibrator | Pressure generation plus pressure measurement; optional current, voltage, or switch testing | Manual pneumatic or hydraulic generation; typical field ranges include vacuum, low pressure, and high-pressure service | Pump-generated pressure is generally verified by an integrated or external reference sensor | On-site calibration of gauges, pressure switches, transmitters, and relief or alarm devices | Pressure medium, achievable range, fine adjustment, leakage control, portability, and contamination prevention |
| Intrinsically Safe Process Calibrator | Usually current, voltage, resistance, frequency, temperature, and selected pressure functions | Designed for use in classified hazardous areas when approved for the applicable zone, division, gas, and dust requirements | Accuracy is comparable to the underlying function but may be limited by safety-approved circuit design | Oil and gas, petrochemical, chemical processing, mining, and other hazardous-location maintenance work | ATEX, IECEx, or local approval, temperature class, equipment group, ingress protection, permitted accessories, and service rules |
| Portable Multifunction Calibrator with Data Connectivity | Process electrical signals, temperature, pressure modules, wireless data transfer, and digital records | Combines several calibration functions with mobile work orders, asset identification, and electronic result transfer | Function-specific accuracy; connectivity does not replace traceable measurement performance | Large multi-site maintenance teams, centralized quality systems, predictive maintenance, and paperless workflows | Cybersecurity, supported protocols, offline operation, battery endurance, data ownership, and integration with maintenance software |