| Basic PDU | Distributes power to connected equipment without local metering or remote communication. | 120 V single-phase 208–240 V single-phase 208 V three-phase | IEC 60320 appliance outlets, locking outlets, or facility-specific receptacles; outlet count commonly ranges from 8 to 42. | No built-in electrical measurement or outlet switching. | 10–60 A, depending on voltage, connector, and installation method. | Small server rooms, network cabinets, laboratory racks, and non-critical equipment. | Lowest purchase cost, simple operation, and fewer electronic components. | Provides little information about load growth, imbalance, or circuit capacity. |
| Metered-Input PDU | Displays the total electrical load at the PDU input. | Single-phase Three-phase Local display | Fixed outlet arrangement selected for the rack voltage and plug type. | Local measurement of voltage, current, power, power factor, and accumulated energy; remote access is normally unavailable. | 16–63 A is common for rack-level units. | Facilities that need local capacity checks but do not require centralized monitoring. | Helps prevent accidental circuit overloading and supports on-site troubleshooting. | Does not normally provide outlet-level data or remote alarms. |
| Monitored PDU | Measures electrical conditions and sends operating data to a management platform. | Single-phase Three-phase Network-enabled | Fixed or mixed outlet groups; outlet-level measurement may be available on advanced configurations. | Remote voltage, current, power, energy, power factor, phase load, thresholds, alarms, and historical data. | 16–63 A is common; higher ratings require coordinated facility protection and cabling. | Medium and large data centers, colocation rooms, and sites with capacity-management requirements. | Improves visibility, capacity planning, alerting, and energy reporting. | Higher cost and requires network connectivity, configuration, and cybersecurity controls. |
| Switched PDU | Provides remote control of individual outlets or outlet groups in addition to monitoring. | Single-phase Three-phase Network-enabled | Controlled outlet banks or individual outlets; outlet sequencing may be supported. | Remote outlet on/off, delayed reboot, outlet current measurement, user permissions, alarms, and event logs. | 16–63 A is common for rack-mounted units. | Remote sites, high-density racks, lights-out facilities, and equipment requiring controlled reboot. | Reduces on-site service visits and supports orderly equipment startup and shutdown. | Incorrect switching can interrupt equipment; access control and fail-safe procedures are essential. |
| Automatic Transfer PDU | Transfers a connected load between two independent power sources when the preferred source fails. | Dual input Same nominal voltage Source monitoring | Usually single-phase rack outlets; output capacity is limited by the PDU rating and source availability. | Source status, input voltage, current, transfer events, alarms, and optional remote communication. | Commonly 16–60 A for rack-level applications. | Single-cord equipment supplied by two separately protected upstream power paths. | Improves availability when one upstream source is lost or removed for maintenance. | Both sources must be compatible; it does not replace a UPS and does not provide battery backup. |
| High-Density Three-Phase PDU | Distributes higher power through multiple phases for dense computing or industrial loads. | 208/120 V three-phase 400/230 V three-phase Wye or equivalent system | Combination of single-phase and three-phase outlets selected according to the connected equipment. | May include per-phase, circuit-level, or outlet-level monitoring and phase-balance alarms. | Commonly 16–63 A at rack level; facility switchboards can be rated substantially higher. | High-density computing racks, industrial control cabinets, and large equipment enclosures. | Higher power capacity, better conductor utilization, and improved phase-load management. | Requires qualified installation, correct phase identification, and careful load balancing. |
| Busway-Mounted PDU Tap-Off | Obtains power from an overhead or underfloor busway and distributes it locally to a rack or equipment row. | Plug-in tap-off Single or three-phase Busway compatible | Usually feeds a rack PDU, distribution panel, or row-level power assembly. | Depends on the connected PDU; optional metering can be installed at the tap-off or downstream device. | Determined by the busway tap-off rating, commonly 16–125 A in modular distribution systems. | Data halls requiring flexible rack deployment and frequent cabinet moves or additions. | Supports modular expansion and can reduce fixed cabling changes during layout revisions. | Must match the busway system, protection coordination, short-circuit rating, and installation rules. |