| Straight splice plate | Joins two tray sections along a straight run. | Use the splice configuration specified for the tray system and span conditions. A connector does not replace required tray supports. | Select a compatible finish or material for the exposure, such as indoor dry, damp, corrosive, or outdoor service. | Align tray ends, use the specified fasteners and hole pattern, and tighten to the system instructions. |
| Expansion splice plate | Accommodates anticipated thermal movement in long runs or locations subject to temperature change. | Movement allowance and support placement must follow the tray system’s engineering guidance; do not lock the joint if it is intended to move. | Consider the operating temperature range and differences in thermal expansion between tray sections and connected structures. | Set the joint gap for the installation temperature and required movement range. Keep the expansion joint clear to travel as designed. |
| Adjustable-angle connector | Connects tray sections where the route changes direction or elevation at a non-standard angle. | Confirm that the selected connector and support arrangement suit the cable load and geometry; angled joints can introduce additional forces. | Match the connector material and protective finish to the tray and the installation environment. | Check the permitted adjustment range, tray alignment, bend radius requirements, and access for tightening fasteners. |
| Vertical splice or riser connector | Joins tray sections on vertical runs or at changes between horizontal and vertical routes. | Vertical cable weight and the tray’s support spacing require particular attention. Use the specified connector and independent supports where required. | For outdoor or corrosive locations, check material compatibility and the condition of protective coatings after installation. | Follow the approved support layout, secure the tray against movement, and observe cable-retention requirements for vertical runs. |
| Bonding jumper | Provides electrical continuity across a joint when required by the tray design or electrical installation. | Choose a listed or otherwise code-compliant bonding method appropriate to the system and fault-current requirements; it is not a structural connector. | Check compatibility with tray material and finish to limit corrosion, especially in wet or chemically aggressive locations. | Install at the designated joints, maintain clean contact surfaces as instructed, and verify continuity when required. |
| Hold-down or tray clamp | Secures tray to a support or helps restrain it where the approved design calls for restraint. | Confirm the clamp is intended for the tray profile and support. Do not assume a clamp increases the tray’s published load capacity. | Use compatible materials and finishes for the support structure and exposure conditions. | Check clamp fit, fastener access, and whether the design requires fixed or sliding restraint to allow movement. |