| 1 | Choose glass for the application | Annealed glass is commonly available in 6–12 mm; tempered glass is often specified at 8–12 mm for interior partitions. | Clear, low-iron, tinted, or patterned. | Use safety glazing where required by local building codes. Tempered glass breaks into small pieces but is not unbreakable. | Confirm panel size, support conditions, impact exposure, and applicable local code before selecting thickness. |
| 2 | Consider laminated glass where fragments must be retained | Common constructions include 3 + 3 mm glass with a 0.38 mm interlayer (about 6.38 mm overall) and 4 + 4 mm with a 0.38 mm interlayer (about 8.38 mm overall). | Clear, colored, translucent, or acoustic interlayers. | The interlayer generally helps hold fragments together after breakage; verify the tested make-up and required safety classification. | Specify glass and interlayer thickness separately, along with edge exposure and intended use. |
| 3 | Compare tempered and tempered-laminated safety options | Tempered monolithic panels are commonly 8–12 mm. Tempered-laminated constructions vary; examples include 4 + 4 mm or 5 + 5 mm plies with an interlayer. | Clear, low-iron, tinted, or surface-treated plies. | Tempered-laminated glass combines heat-treated plies with fragment retention. The complete make-up must meet the project’s safety requirements. | Check whether the specification requires post-breakage retention, impact resistance, or both. |
| 4 | Match thickness to the complete partition system | Common interior panel thicknesses include 8, 10, and 12 mm; laminated assemblies are thicker and depend on the selected plies and interlayer. | Thickness can be combined with clear, frosted, or patterned finishes. | Panel dimensions, fixing method, deflection, and impact loads affect suitability; thickness alone does not establish safety. | Request project-specific engineering or system guidance for large, tall, or minimally supported panels. |
| 5 | Select a finish for privacy and light transmission | Clear or low-iron glass is often selected for transparency; translucent finishes can be applied to suitable glass types and thicknesses. | Acid-etched, sandblasted, ceramic-frit, patterned, or applied privacy film. | A finish changes visibility, not necessarily impact performance. Confirm compatibility with tempering or lamination where relevant. | Review a physical sample under the project’s lighting and confirm which surfaces receive the finish. |
| 6 | Plan edgework and hardware details early | Edgework requirements depend on the panel thickness, fixing system, and whether the glass is monolithic or laminated. | Flat-polished, seamed, or otherwise specified edges; hardware cut-outs and holes must be planned. | Tempered glass generally cannot be cut, drilled, or edge-worked after heat treatment without risk of breakage. | Approve final dimensions, tolerances, holes, notches, and edge details before tempering or lamination. |
| 7 | Check standards and test evidence for the destination market | Performance depends on the exact glass construction, processing, and intended application—not just nominal thickness. | Request finish samples and product documentation for the specified make-up. | Examples of relevant references include EN 12150 for thermally toughened glass, EN 12600 for pendulum impact testing, ANSI Z97.1, and CPSC 16 CFR 1201. Applicability varies by market and use. | Ask for current test reports or declarations covering the exact product and the code required by the project jurisdiction. |
| 8 | Set realistic expectations for acoustic privacy | Acoustic performance depends on glass build-up, panel size, seals, framing, and gaps; laminated glass may be specified as part of an acoustic design. | Clear, frosted, or patterned options can be considered independently of the acoustic target, subject to product compatibility. | A single glass-panel rating does not represent the performance of the installed partition if sound leaks through joints, doors, or ceilings. | Specify a tested system target, such as an applicable sound-transmission rating, and check seals, doors, and perimeter details. |
| 9 | Account for heat, sunlight, and color appearance | Tinted, coated, or laminated glass may be available in different thicknesses; suitability depends on the full product configuration. | Body-tinted, coated, low-iron, or colored-interlayer options. | Thermal-stress risk can depend on solar exposure, shading, edge conditions, and glass type. Coatings may need to be positioned on a specified surface. | Request samples and confirm coating orientation, visible color, light transmission, and any thermal assessment required. |
| 10 | Verify fabrication, packing, and delivery requirements | Confirm nominal thickness and finished dimensions for every panel, including any laminated make-up and hardware preparation. | Record finish, pattern direction, finished faces, and edge appearance in the order documents. | Inspect for damage and keep glass protected during handling and installation; chipped edges can create breakage risks. | Agree on drawings, tolerances, panel identification, protective packing, handling instructions, and inspection procedures before production. |